SEVERNCLINICS

Optokinetic tool

Personal visual-pattern tool

Saved on this device
Help me set up the tool

Answer a few questions to prepare your display.

Nod · chin down and up

Use this option if your clinician gave you Nod instructions and settings.

ReadyChoose your settings
Direction unset · speed unset · duration unset

Your display is ready

Choose a direction, speed and duration.
Nothing moves until you press Start.

--:--remaining
WHAT NEXT

Select a stripe direction, set a speed and choose your session duration.

The screen should fill 80% of your field of vision.

Saved presets 0

Save a setup for later. Loading a preset never starts playback.

Session log 0

Actual active time is recorded. Guide previews are labelled separately. Add optional notes after a session.

Personal five-day planner Optional

A personal tracking template, not a required dose. Empty and skipped slots are normal. It never starts a session.

DIRECTION CHOOSER

What are you using this for?

Start with your situation. Only the questions relevant to it will appear.

Your situation

Your answers stay in this dialog; the tool saves the settings you apply. This is a research aid, not a diagnosis.

OFFLINE GUIDE

How to use your tool

Follow the movement your referring clinic specified. Tilt means ear towards shoulder. Nod means chin down and up. If your referral does not specify which to use, check with the clinic before starting. You can stop the display at any time with Stop + blank or Escape.

Tilt: the direction chooser and Reference example

The head faces forward. Each ear tilts towards the shoulder on the same side. The guide shows about 20° each way. The head tilt cycle is the time to travel left, right and back to left. The default is six seconds.

In the published standardised protocol, a clinician moved the patient’s head by hand. The illustration shows the movement used in that setting. Consult a practitioner experienced in MdDS about its suitability for you.

To see the movement on its own, load the Reference example and press Preview movement · no stripes. The animated head, angle line and metronome are on by default. Screen-left is your left.

With the default clicks, you hear a click as the head passes upright and a quieter click as it passes upright on the way back. Select Seven-note guide for a melody that rises as the head moves from left to right and falls on the return. The lowest and highest notes mark the two ends of the tilt.

Nod: when your clinician has given you instructions

In Dr Yakushin’s pilot study, a clinician guided the head chin down and up for patients who felt they were swaying from side to side. The team selected the pace for the individual. The study treated a steady pull to one side as a different symptom. Neither the chooser nor the Reference example selects Nod.

Choose Enter Nod instructions. Confirm that you have instructions, then enter the full cycle in seconds, stripe speed and session duration provided by your clinician. A clinician can also enter them with you. Choose the stripe direction they specified, or leave it blank to preview the head alone. If any instructions are missing, check with the referring clinic. Applying settings does not start playback. The up/down marker shows timing; it does not specify a head angle. Use Return to standard Tilt to leave this mode.

What to ask your clinic for: the time for one complete chin-down → chin-up → chin-down cycle, the stripe direction and speed, and how long to run the session. With the default sound settings, the tool clicks twice per full cycle. If your instructions give only a metronome beat, check what it refers to before entering a cycle time.

Setting up the stripes

  1. Choose the stripe travel direction. Use the direction control or open Help me choose direction. You can enter a direction yourself. If you already have instructions from your clinician, enter the direction the stripes should travel across the screen.
  2. Review the chooser result. For some descriptions of a lateral pull, the chooser shows a direction reported in research. Other answers can leave the direction unset. You can change the direction before applying a setup. Your answers stay in the dialog. A questionnaire cannot reproduce the clinical assessment used in a study.
  3. Review and apply your setup. The chooser and Reference example start at 60 pixels per second, with a four-minute session, head tilt, angle line and metronome. Three- and five-minute sessions are also available. This screen-based software speed needs no measurement and is not the same as 10 degrees per second.
  4. Start when ready. Sit in a stable chair, clear nearby trip hazards and locate Stop + blank. The stationary point in the middle is the fixation reference. The display and timer stop at the chosen duration. There is no automatic repeat.

The field-of-vision note refers to how much of your view the display occupies. This tool cannot measure 80% of your field of vision. Avoid moving uncomfortably close to the screen to try to reach that figure.

The separate clinician-directed Nod option uses the speed supplied in degrees per second. For that option, Measure screen asks for the ruler-measured line length and your eye-to-screen distance. Those measurements belong to the screen and viewing position you use; pixel-speed playback does not need them.

Playback and records

Pause blanks the display, silences it and holds the remaining time. Stop + blank or Escape ends the session. Full screen expands the display. Leaving full screen stops playback. Switching away from the tab pauses playback.

You can adjust stripe colours, band widths, gaps, brightness and contrast. The centre point and the tilt guide have separate roles. Choose stripes only if you want to hide the head. Use the volume control or turn off the metronome for silence.

Optional session notes and the five-day planner stay in this browser. Its slots are for record keeping. Your clinician can advise you on a home schedule. The planner never starts a session. Export a backup to move your presets and records to another browser or device. Importing a backup asks before replacing your data.

Clinical sources

The original readaptation study describes clinical direction selection and supervised sessions.

The 2024 standardised protocol describes clinician-guided head tilt and a six-second cycle with stripes moving at 10° per second. The tool’s 60-pixel/second setting is a different software setting. Mount Sinai’s patient guidance is in Clinical guidance beside Start. The Epilepsy Foundation explains sensitivity to visual patterns.

Measure this screen

Measure the distance between the two end marks with a ruler. Enter centimetres, then your eye-to-screen distance.

400 CSS pixels

This is a geometric conversion near screen centre. Angular speed varies across a flat screen; this is not clinical calibration.

Session notes

Blank scores stay unrecorded. Add a later score whenever you choose; no reminders are sent.

Confirm change

Planner slot